Solutions · Slurry loss

Slurry Loss Emergency Response Plan

An emergency response flow for sudden slurry loss and collapse warning signs — plugged within 2 hours and back to work fast.

Solution overview

Application methods
旋挖灌注桩施工 / 非开挖管线施工 / 钻探与钻井施工
Problem type
Slurry loss

Scenario and construction challenges

Sudden slurry loss in pipe jacking and drilling: escaping slurry triggers surface settlement or even collapse, so the leak must be located, plugged and wall protection restored in hours.

Challenge 1Hidden leak

Loss channels run underground — their location and path cannot be seen directly.

Challenge 2Clock ticking

A growing leak leads to surface collapse, leaving a response window measured in hours.

Challenge 3Secondary collapse

Any delay hollows out the ground and invites secondary collapse and accidents.


Complete solution

Each scheme pairs materials with dosing; the table below lists material, role and ratio per step.

StageMaterialFunctionRatio / dosageWorking conditionScope
PlugRapid-set loss-circulation agentSeal the leak point fastTrial-mixed per leakSudden loss with settlement warning signsSand / backfill zones with a located leak
Wall protectionPAM-S concentrated slurryRe-film and restore protection1:200After plugging, protection must be restoredPipe-jacking / drilled bore walls
PressureBENT-N thick slurryBackfill cavities, steady pressure10%–12%Falling hole level requiring pressure supportBackfilling loss channels
MonitorSettlement monitoringTrack settlement and returnsEvery 2 hoursThroughout the responseRoads and utilities above the crossing
iWorking conditions and scope in the reference mix table are typical values; actual dosages must be confirmed by on-site trials with raw water, soil samples and project design, and do not constitute a performance commitment.

Delivered results

2 hours
Time to plug
3 days
Earlier work resumption
0
Secondary collapse incidents
✓The figures above are measured data from this project (indicative). Actual performance varies with strata and working conditions; a full case report is provided together with the delivered solution.

Construction schematic & site photos

Use the schematic and site photos to follow the process and slurry flow; final parameters follow on-site trial results.

Construction schematic

① Locate the leak ② Rapid-set plugging ③ Restore wall protection ④ Settlement and return monitoring

Site photos

Surface works at loss zone
Plugging grout operation

Related cases

GET A QUOTE

Tell us your strata conditions —
get tailored selection advice

Share your strata, borehole diameter and schedule; engineers will reply with mix advice, quantity estimates and lead time. Your information is used only for this enquiry.

✓On-site strata compatibility assessment (per project arrangement)
✓Batch test report & certificate with every shipment
✓On-site mix commissioning by our engineers (per project arrangement)
✓Samples and product brochures on request
Sales hotline
Business email
Form mode
For a quick conversation, leave your name, phone and a short message. Choose detailed project requirements if you have strata, borehole diameter or schedule data.
Filled in from the entry point you used; you can change it
Additional strata (multiple choices)
We will contact you to discuss your requirements.